Super clean emission wet soot meter SBF800

    The SBF800 system has a jet fan and a dilution fan. After the system is powered on, it heats the entire pipeline. Before the system reaches the sampling temperature, the jet fan first purges the sampling probe tube. After the heating temperature reaches the set temperature, the valve switches to the flue gas sampling state. The negative pressure generated by the jet pump sucks the sample gas into the sampling probe rod. At the same time, the heated dilution air quickly mixes with the sampling flue gas in the front of the probe rod and heats it into dry flue gas, Finally, enter the measurement unit to measure the dust concentration.
24-hour free hotline:021-58557312
  • Characteristic
  • Application
  • Authentication
  • System components
  • Technical parameter
  • Download

lThe dilution heating probe and the measuring unit are integrated, with compact design and short sample gas transmission route

lPerfect isokinetic sampling system

lThe dilution sampling system can set the dilution ratio according to the particle concentration under working conditions to improve the accuracy of measurement

lDilution heating can quickly heat wet flue gas into dry flue gas, which is suitable for various temperature and humidity conditions

lThe system has its own fan to provide high-temperature blowback, which can effectively prevent probe pollution, with small maintenance amount and long maintenance interval

lIt has the function of automatic zero point and range calibration, and automatically cleans and calibrates the optical mirror surface

lOptional multi-point sampling nozzle with multi-point sampling function

lWith automatic range switching function

lWith self-protection function, the sampling pipeline can be closed even after the system is powered off to protect the equipment from being polluted.


 



Factories where soot concentration needs to be measured, such as:

lthermal power plant

lCement industry

lSteel industry

lPetrochemical industry

lindustrial boiler 

lConverter and asphalt mixing yard

lOther sewage discharge enterprises




lList of applicable measuring equipment included in continuous emission monitoring

lPassed China National Metrology Certification

lPassed the China National Environmental Protection Certification



1559542866305811.png


Previous:None
Next:Smoke detector D-R 8002022-11-17
Message
*Mandatory Field

Yes, I have read and understood the privacy policy, and I agree that the data provided by me will be collected and stored electronically;

My data can only be used strictly to process and answer my requests;

By submitting the contact form, I agree to this process.    

Note: After processing the request, the data will be deleted.

Contact

    Tel:+86 21 58557312

    Email:sales@sh-baif.com

    Address:Building 2, South Area, Zhangjiang First Field, No. 33 Chuantu Road, Pudong New Area, Shanghai